MODEL NUMBER |
|
MODEL |
|
375A |
Vibraswitch detector incorporating electronic starting & time delay
functions. Enclosure meets explosion-proof, Class I Division 1, Groups C & D,
and Class II, Division I, Groups E, F & G specifications. Range 0-4.5G, 10 to
300 Hz. Reset control by push button on unit or remote electrical contact.
0-Ring shaft seals standard. |
|
|
376A |
Same as above, except designed for non-hazardous locations. Water-tight and
general purpose enclosures meets NEMA 3, 4 & 5 specifications. |
|
|
SUPPLY VOLTAGE |
|
A |
120 VAC +/- 10%, 50/60 Hz |
|
|
CONTROL FUNCTIONS |
|
1 |
Starting time delay function only. Output: Mechanical contacts SPDT (See
specifications for rating) |
|
| 2 |
Monitoring time delay function only. Output: Solid-State switch. (See
specifications for rating) |
|
| 3 |
Combination starting and monitoring time delay function. Output: Solid-State switch.
(See specifications for rating) |
|
|
STARTING TIME DELAY |
|
A |
None - always used with Designation 2 from Table 2. |
|
|
C |
15 seconds |
|
|
D |
30 seconds |
|
|
E |
60 seconds |
|
|
F |
90 seconds |
|
|
MONITORING TIME DELAY |
|
0 |
None - always used with Designation 1 from Table 2. |
|
|
2 |
2 seconds |
|
|
3 |
5 seconds |
|
|
4 |
10 seconds |
|
|
ACCESSORY ITEMS |
|
904GB016 |
Rainshield for unprotected outdoor installation. Model 375A only. |
|
|
904GB016-03 |
Rainshield - Epoxy Painted |
|