STANDARD FEATURES
Size: 6"
dial
Scale length:
16"
Range: To
100 psi
Accuracy:
0.33% of full scale
Sensitivity:
0.2% of full scale
Pressure
element volume: 2.5 cc for the range 0-10 water; 2.0 cc for all other
ranges.
Case volume:
1890 cc, with overpressure relief valve on the case
Maximum case
pressure: 15 psig
Maximum case
leak rate: Will not exceed 6.34 x 10-5 std cc/sec or 0.0018 psi/hr
Case
connection: 1/8" female NPT pressure and static connections. Both have
built-in stainless steel filters and are located in the bottom of the
case.
Case
construction: Cast aluminum with tempered-glass dial cover. Flush
mounted by three screws through the bezel.
Materials
exposed to measured gas:
Pressure
elements: beryllium copper, brass, soft solder in ranges to 100
water; silver and soft solder in ranges above 100 water.
Case:
aluminum, beryllium copper, brass, stainless steel, nylon, Hypalon,
Monel, soft solder, synthetic sapphire, TFE, white paint, drawling ink,
Duco lacquer. Ranges above 100 water have silver solder also.
Options:
Calibration in most metric units is available at no extra cost. Other
units of calibration and two sets of graduations on the same dial are
available at extra cost.