STANDARD FEATURES
Size: 8½"
dial
Scale length:
Approx. 45" through 2 pointer revolutions
Range: To
150 psi
Accuracy:
0.066% of full scale
Sensitivity:
0.01% of full scale
Hysteresis: 0.1% of full scale for all ranges except 150 psi or
equivalent, which is 0.2% of full scale
Maximum
temperature effect: 0.1% of full scale per 10°C/50°F change from 23°C/
73.4°F
Pressureelement volume: 6.9 cc with pointer at zero; 8.6 cc at full
scale.
For the range
0-125 water only: 6.3 cc with pointer at zero; 8.0 cc at full scale
Case volume:
3070 cc
Maximum case
pressure: 35 psig
Maximum case
leak rate: Will not exceed 1.03 x 10-3 std cc/sec or 0.018
psi/hr
Case
connections: 1/8" female NPT pressure and static connections.
Stainless steel filters are mounted in the orifice of both units and are
located in the bottom of the case.
Case
construction: Cast aluminum with tempered-glass dial cover; flush
mounted by three screws through the bezel.