STANDARD FEATURES
Sizes:
8½" dial
Scale length:
To 500 psia
Accuracy:
0.066% of full scale
Repeatability: 0.03% of full scale
Sensitivity:
0.01% of full scale
Hysteresis:
Below 100 psia, 0.15% of full scale; 100 psia and above, 0.1% of full
scale
Maximum
temperature effect: Below 100 psia, 0.019% of
full scale per 10°C/ 50°F change from 23°C/73.4°F; 100 psia and above,
0.1% of full scale per 10°C/50°F from 23°C/73.4°F.
Case pressure
and volume: For gauges with ranges below 100
psia, maximum case pressure is 35 psig, case volume is 3070 cc. For gauges
with ranges of 100 psia and above, volume of the pressure Bourdon system
is 10 cc and the case is vented to atmosphere.
Maximum case
leak rate: Will not exceed 1.03 x 10-3 std
cc/sec or 0.018 psi/hr in ranges below 100 psia; 100 psia and above, case
is vented to atmosphere.