BSI Controls (Buck Sales Inc.)
Home  | Products  | Manufacturers  | Applications Literature  | Contact  | Search
Glass tube Purge Meter

The Wallace & Tiernan Glass Tube Purge Meter is meant for low flow applications for gas or liquid. They can stand pressure of 200 psig with a temperature of 200 ºF. (See the Data Sheet for limits with different options) The glass tube and float is easy to replace while the meter is inline and the stainless steel frame gives excellent corrosion resistance. Connections are 1/4" FNPT and are horizontal


 
The Model Number for the Glass Tube Purge Meter consists of 12 characters arranged in 8 groups
GROUP POSITION DESCRIPTION
1

1

2

BASIC METER ARRANGEMENT

2

3

4

5

6

TUBE, SCALES, & FLOAT

3

7

O-RING MATERIAL

4

8

TUBE RETAINER MATERIAL

5

9

OPTIONAL FLOW CONTROLLER

6

10

OPTIONAL BEZEL

7
11

CONTROL VALVE LOCATION

8
12

TAG

Download Specifications
Data Sheet
Dimensions

Dimensions-
 GTPM Controller Out

 

 

How to configure the Glass Tube Purge Meter

Check for Accuracy

These meters have an accuracy of 10% of Full Scale. If you need 2%; you need the Low Flow Meter

Length of Tube

In position 6 enter "1" for 1-1/2" Tube or "3" for 3" Tube. Accuracy is the same for either

Flow Range, Units and Capacity

From either the 1-1/2" or the 3" table select the desired flow and then put the two digit CODE in position 4, 5. In position 3 put the code for the units: "A" = gph, "B" = ccm, "E" = sccm or scfh. For Liquid % use "C" and for Gas % use "D"

Please contact us if you need extra low flow (less than 0.1 gph, 30 ccm or 1.0 scfh)

Liquid: ccm (cubic centimeters per minute); gph (gallons per hour), or %. Standard is water

Gas: sccm standard cubic centimeters per minutes; scfm (standard cubic feet per minute),or %. Standard is Air.

Special tubes are available, but they are expensive and the delivery time is long.

O-Ring Material:

For Buna-N or Viton put an "S" in position 7; for EPR put "1"; for Kalrez put "K". Also, put a "3" in position 1 for viton or "2" for all others

There are four materials for O-Rings: Buna-N, Viton, EPR, and Kalrez 4079. Use the Material Selection Guide for assistance. Buna-N and Viton are the standard and are least expensive

Valves

If no valve is required, put a "0" in position 2 and an "X" in position 11. Under the CAPACITY column in the 1-1/2" or 3" Tube table select the type (knob or slot) which matches  the CODE and put the value in position 2. In position 7 put "2" for an inlet valve or "3" for an outlet valve

The meters are available with or without a valve. The valve can be on the inlet (typical for liquids) or the outlet (typical for gases - although not a firm rule). The valves come in two types: "with Knob" which has a standard knob for adjustment of the flow and "with Slot" which has a screw driver slot covered by a cap - used when accidental adjustment of the flow is of concern

Controllers

From the FLOW CONTROLLER table enter the alphabetic character in position 9. Enter "X" if there is no controller

Controllers which keep the flow constant with varying pressure are available in brass or stainless steel and for the inlet and outlet

Bezels

In position 6 enter "X" for no bezel, "1" if there is no control valve and "2" if there is a control valve.

Bezels are available for mounting the meter flush in a panel

Tagging

In position 12, enter an "X" for no tagging or a "1" for tagging

Factory wired-on stainless steel tagging is available

Retainers

In position 8, enter an "S" for the standard kynar or a "1" for stainless steel

For applications where is standard kynar retainer is not acceptable, a 316 SS retainer can be provide. This also for a maximum pressure of 250 psig and 250 ºF with viton and EPR O-Rings

 
1-1/2" TUBE
Liquid (Water) Gas (Air)
CAPACITY CODE gph ccm sccm or scfh
KNOB SLOT A B E
2 6 07     1.0 scfh
2 6 08 0.5 gph   2.5 scfh
2 6 09 1.0 gph 60 ccm 6.0 scfh
2 6 10 3.0 gph 180 ccm 12.0 scfh
2 6 11 5.0 gph   30.0 scfh
4 8 12 8.0 gph 500 ccm 20.0 scfh
4 8 13 15.0 gph 900 ccm 36.0 scfh
4 8 14 25 gph 1500 ccm 60.0 scfh
4 8 15 40 gph   110 scfh

 

3" TUBE
Liquid (Water) Gas (Air)
CAPACITY CODE gph ccm sccm or scfh
KNOB SLOT A B E
2 6 07 0.1 gph   1.0 scfh
2 6 08 0.5 gph 30 ccm 2.5 scfh
2 6 09 1.0 gph 60 ccm 6.0 scfh
2 6 10 3.0 gph 180 ccm 12.0 scfh
2 6 11 5.0 gph   30.0 scfh
4 8 12 8.0 gph 500 ccm 20.0 scfh
4 8 13 15.0 gph 900 ccm 36.0 scfh
4 8 14 25 gph 1500 ccm 60.0 scfh
4 8 15 40 gph 2500 ccm 110 scfh

 

FLOW CONTROLLER

LOW CAPACITY (2,6) HIGH CAPACITY (4,8)

MATERIALS

INLET (2) OUTLET (3) INLET (2) OUTLET (3)
BRASS & BUNA-N DIAPHRAM N (5830) P (5840) Q (5870) R (5880)
STAINLESS STEEL & TEFLON DIAPHRAM S (5810) T (5820) U (5850) Y (5860)

 
Controllers & Displays · Flow · Level · Pressure · Temperature · Valve Automation · Vibration · Weight

Annunciators · Actuators · Bimetal Thermometers · Calibrators · Control Valves · Differential Pressure Gauges · Digital Controllers · Excess Flow Valves · Flow Controllers · Flowmeters ·  Flow Transmitters · I/P Converters ·  Large Panel Displays ·  Level - Capacitance ·  Load Cells · Loop-Powered Meters · Pneumatic Controls · P/I Converters · Pressure Gauges · Precision Pressure Gauges · Pressure Regulators ·  Pressure Snubbers · Pressure Transmitters · Process Meters · Rotameters · Self Actuated Temperature Regulators (SATR) · Solenoid Valves · Summing Units · Temperature Controllers · Temperature Meters · Temperature Regulators · Thermometers · Totalizers · Valve Positioners · Vibration Detectors · Vibration Monitors · Vibration Switches · Vibration Transmitters · Web Tension · Weight Indicators

 